STEEL CHANNEL
COLUMN LOAD DATA

gs015b.gif (5161 bytes)


 

gs017b.gif (30562 bytes)

The distance between beams positioned on any one axis of the column, or total height of the column if beams are positioned on only one axis of the columns: loads shown assume column to be steel, regular channel only. Check column strenght for both.

  1. Allowable loading on greatest unbraced height.
  2. Allowable loading on unbraced height at base of column, where maximum load occurs.

 



gs017c.gif (4361 bytes)
gs017d.gif (12384 bytes)

Steel section properties are based on metal thickness as defined by the AISI Cold Formed Steel Design Manual